Knucklehead Reverb 1.0 p 19
Mains Fuse
This AC line fuse protects your amplifier from damage due to shorts, momentary
surges, and defective power tubes. In the event of a fuse failure, always replace it with
the same type of fuse.
For 100VAC 55 versions, the Mains Fuse is:
3 Amp, 250 Volt Slo-Blo type (size 3AG, or MDL).
For 100 versions, the Mains Fuse is:
5 Amp, 250 Volt Slo-Blo type (size 3AG, or MDL).
For 115VAC 55 versions, the Mains Fuse is:
3 Amp, 250 Volt Slo-Blo type (size 3AG, or MDL).
For 100 versions, the Mains Fuse is:
4 amp, 250 Volt Slo-Blo type (size 3AG, or MDL).
For 230/250VAC 55 versions, the Mains Fuse is:
T 1.6A (time-delay, 5mm x 20mm size).
For the 100 Versions, the Mains Fuse is:
T 2A (time-delay, 5mm x 20mm size).
Warning: If the Mains Fuse or the HT Fuse repeatedly blows, refer your
amp to your local RIVERA dealer or contact us at (818) 833-7066 for
further service assistance.
Note: Always turn the amp off and wait about five minutes before
replacing a fuse. This allows the parts to cool and high voltages to
dissipate.